AC-output relay for resistive and inductive loads. Fast switch-off.
| Primary | SLO 5IRA | ||
| Input voltage | nominal | VDC | 5 |
| Input current | typical | mA | 12 |
| maximum | mA | 15 | |
| Input voltage range | minimum | VDC | 3 |
| maximum | VDC | 7 | |
| Input impedance | typical | kΩ | 0,42 |
| Switch-on voltage | typical | VDC | 2,7 |
| maximum | VDC | 3 | |
| Switch-off voltage | typical | VDC | 2,5 |
| minimum | VDC | 2,0 | |
| Secondary | SLO 5IRA | ||
| Load voltage | minimum | VAC/VDC | 0/0 |
| nominal | VAC/VDC | 240/250 | |
| maximum | VAC/VDC | 265/300 | |
| Load current | maximum | A | 1,2 |
| Voltage drop at maximum load | typical | VAC | 2 |
| Switch-on delay | typical | ms | 0,3 |
| maximum | ms | 0,5 | |
| Switch-off delay | typical | ms | 0,3 |
| maximum | ms | 0,5 | |
| Load inductance at 240 VAC 1,2 A | range | cos Φ | 0,3...1 |
| Leakage current (off-state) | typical | mA (AC) | 0,05 |