SLO 24CRAA4

DC-output relay for inductive loads and to cut off high DC voltages.

 

 

Datasheet
Qualifications checkbox_on CE checkbox_on RoHS
Delcon
MTTF (Mean Time To Failure): 30,8 years
PrimarySLO 24CRAA4
Input voltagenominalVDC24
Input currenttypicalmA12
maximummA15
Input voltage rangeminimumVDC18
maximumVDC32
Input impedancetypicalkΩ2
Switch-on voltagetypicalVDC16
maximumVDC18
Switch-off voltagetypicalVDC14
minimumVDC12
SecondarySLO 24CRAA4
Load voltageminimumVDC0
nominalVDC350
maximumVDC380
Load currentmaximumA4
Voltage drop at maximum loadtypicalVDC0,6
Switch-on delaytypicalms0,3
maximumms0,5
Switch-off delaytypicalms0,3
maximumms0,5
Load inductance at 350 V 4 A, L/Rmaximumms4
Load inductance at 24 V 4 A, L/Rmaximumms50
Leakage current (off-state)maximummA1