DC-output relay for resistive and minor inductive loads. Low input current.
| Primary | SLO 24CL | ||
| Input voltage | nominal | VDC | 24 |
| Input current | typical | mA | 1,8 |
| maximum | mA | 2 | |
| Input voltage range | minimum | VDC | 18 |
| maximum | VDC | 32 | |
| Input impedance | typical | kΩ | 13 |
| Switch-on voltage | typical | VDC | 16 |
| maximum | VDC | 18 | |
| Switch-off voltage | typical | VDC | 14 |
| minimum | VDC | 12 | |
| Secondary | SLO 24CL | ||
| Load voltage | minimum | VDC | 0 |
| nominal | VDC | 60 | |
| maximum | VDC | 66 | |
| Load current | maximum | A | 3 |
| Voltage drop at maximum load | typical | VDC | 0,5 |
| Switch-on delay | typical | ms | 0,1 |
| maximum | ms | 0,2 | |
| Switch-off delay | typical | ms | 1 |
| maximum | ms | 2 | |
| Load inductance at 60 V 3 A, L/R | maximum | ms | 0,5 |
| Load inductance at 24 V 2 A, L/R | maximum | ms | 5 |
| Leakage current (off-state) | maximum | mA | 1 |