SLO 12CR

DC-output relay for resistive and slightly inductive loads. 

Datasheet
Qualifications checkbox_on CE checkbox_on cULus
Delcon
MTTF (Mean Time To Failure): 137,0 years
PrimarySLO 12CR
Input voltagenominalVDC12
Input currenttypicalmA9
maximummA12
Input voltage rangeminimumVDC9
maximumVDC18
Input impedancetypicalkΩ1,3
Switch-on voltagetypicalVDC8
maximumVDC9
Switch-off voltagetypicalVDC7
minimumVDC6
SecondarySLO 12CR
Load voltageminimumVDC0
nominalVDC60
maximumVDC66
Load currentmaximumA3
Voltage drop at maximum loadtypicalVDC0,5
Switch-on delaytypicalms0,3
maximumms0,5
Switch-off delaytypicalms0,3
maximumms0,5
Load inductance at 60 V 3 A, L/Rmaximumms0,5
Load inductance at 24 V 2 A, L/Rmaximumms5
Leakage current (off-state)maximummA1