SLI 48CR

DC-input relay for limit switches. 

 

 

 

Datasheet
Qualifications checkbox_on CE checkbox_on RoHS checkbox_on cULus
Delcon
MTTF (Mean Time To Failure): 525,1 years
PrimarySLI 48CR
Input voltagenominalVDC48
Input currenttypicalmA6
maximummA7
Input voltage rangeminimumVDC40
maximumVDC70
Input impedancetypicalkΩ8
Switch-on voltagetypicalVDC36
maximumVDC40
Switch-off voltagetypicalVDC26
minimumVDC20
SecondarySLI 48CR
Load voltageminimumVDC0
maximumVDC60
Load currentmaximummA50
Voltage drop at typical loadtypicalVDC0,2
Voltage drop at maximum loadmaximumVDC0,4
Switch-on delaytypicalms0,3
Switch-off delaytypicalms0,3
Leakage current (off-state)maximumµA1